Search

You Are Here:Home > Product > Novastar > Accessory

MFN300-B Function Box

Nova M3 MFN300 Function Box Specifications Ver 2.0.0 2014-2-20 1 Functions Nova M3 MFN300-B is a multi-function box with a variety of auxiliary functions. It has the following characteristics: 1) RS232 serial or Gigabit Ethernet port communication; 2) Support Ethernet port connection between two......

Send InquiryChat Now

Nova M3 MFN300 Function Box Specifications 

Ver 2.0.0 2014-2-20


1 Functions

blob.png

Nova M3 MFN300-B is a multi-function box with a variety of auxiliary functions. It has the following characteristics: 

1) RS232 serial or Gigabit Ethernet port communication; 

2) Support Ethernet port connection between two receiving cards or at the end; 

3) Has timer function, can replace timer and delayer;

4) Support temperature detection of power distribution box;

5) Support humidity detection of power distribution box;

6) Support audio output;

7) Support 2-way light sensor connection, achieve automatic brightness adjustment; 

8) Support Temperature and humidity module connection;

9) Supports 8-way power switch control;


2  Dimensions and interface

MFN300-B Function Box1123.png

Fig. 1 MFN300-B dimensions

 

L GHT SENSOR: Light sensor interface, Temperature and humidity module interface. 

UART: RS232.

AUDIO: Audio output.

DATA: Ethernet port,connect to sending board or scan board. 

CH1~CH8: 8 road power switch terminal.


3  Connection


● Connect function box to computer directly by RS232 serial cable.

MFN300-B Function Box1641.png

● Connect function box between sending card (or independent controller) and the first receiving card.

MFN300-B Function Box1750.png

● Connect function box to the last receiving card.

MFN300-B Function Box1855.png


4  Software configuration

Run NovaLCT-Mars control software, click Function Card button to open Function Card Management page.

blob.png

Use the menu in above Figure to configure function card, including add, remove, rename a function card, modify serial port, and replace serial port.

 

Add:

Ø Serial port: Add a function card which is connected to the serial port. 

Ø Ethernet port: Add a function card which is connected to the Ethernet port. 

Remove: Remove the selected node which could be a function card, Ethernet port, sending card or serial port. 

Rename: Rename the selected function card. 

Serial port operation:

Click blob.png icon to select Modify Serial Port or Replace Serial Port.

Ø Modify Serial Port: Set the selected serial port as one that no function card has been configured for it.

Ø Replace Serial Port: replace the selected serial port with the one which is configured but the configured device type is different from that actually connected, or is actually not connected.

Note: The icon is only available when the following requirements are 

satisfied: The selected node is a serial port; the device connected to it does not match the one configured to it, or the serial port is not connected.


5  Working conditions

blob.png 


Hot Tags: MFN300-b function box, China, manufacturers, suppliers, factory, customized, wholesale, price, pricelist, quotation, made in China
Related Products